Plastics Regrind - Used equipment
Known Issues:
6 Regrind cells
Not all cells are used at the same time
Some cells are used much more than others, due to size
Need to reduce electrical consumption
Need to eliminate Heat loss in the winter months
January indoor temps 70 degrees F and Outdoor air temps as low as -50 degrees F
Budget would not allow for New Equipment
Provided Solutions:
Located a used collector and fan that met air volume and static pressure system requirements. Donaldson Torit Model DFT 3-24.
Located aftermarket silencer (80 dBA) to reduce noise levels when returning air back into building.
Provided heated solenoid enclosure to keep valves from freezing in the winter months.
Provided Delta P Plus filter cleaning control (digital photohelic gauge) to manage filter cleaning and provide alarm (strobe) when filters are no longer viable.
Built custom inlet plenum to allow for multiple duct connections to dust collector.
Connected each regrind cell to collector independently to allow for independent use.
Built custom control cabinet with VFD and air flow control system to provide air only to cells that are in use.
Used compressed air driven automatic blast gates to open/close duct lines independently.
Used clamp together duct work to allow for mobility.
Returnede cleaned air into the building to limit winter heat loss and eliminate the need for make up air.